Wind loading on vertical panels with different permeabilities

Αποθετήριο DSpace/Manakin

Εμφάνιση απλής εγγραφής

dc.contributor.author Giannoulis, A en
dc.contributor.author Stathopoulos, T en
dc.contributor.author Briassoulis, D en
dc.contributor.author Mistriotis, A en
dc.date.accessioned 2014-06-06T06:52:12Z
dc.date.available 2014-06-06T06:52:12Z
dc.date.issued 2012 en
dc.identifier.issn 01676105 en
dc.identifier.uri http://dx.doi.org/10.1016/j.jweia.2012.02.014 en
dc.identifier.uri http://62.217.125.90/xmlui/handle/123456789/5901
dc.subject Design codes en
dc.subject Numerical simulation en
dc.subject Porosity en
dc.subject Vertical panel en
dc.subject Wind loads en
dc.subject.other Design codes en
dc.subject.other Geometrical forms en
dc.subject.other Porous structures en
dc.subject.other Proper design en
dc.subject.other Research studies en
dc.subject.other Vertical panel en
dc.subject.other Wind action en
dc.subject.other Wind load en
dc.subject.other Wind loading en
dc.subject.other Aerodynamic loads en
dc.subject.other Computer simulation en
dc.subject.other Loads (forces) en
dc.subject.other Porosity en
dc.subject.other Research en
dc.subject.other Wind stress en
dc.subject.other Design en
dc.title Wind loading on vertical panels with different permeabilities en
heal.type other en
heal.identifier.primary 10.1016/j.jweia.2012.02.014 en
heal.publicationDate 2012 en
heal.abstract A review of previous research studies on wind loads on vertical panels is presented. This review includes all cases of vertical panels, namely non-permeable and permeable panels on the ground or elevated panels. Two different design codes, The European code on wind actions and the American design code, are examined and their guidelines for the proper design of vertical panels under wind action are presented and compared to the research work found in literature. Impermeable vertical panels on the ground are an extensively studied issue and there seems to be an agreement between previous works and design codes. Results provided on permeable vertical panels show wind load reduction only as a function of porosity. However, the aerodynamic behavior of a permeable panel is affected by the geometrical form of its porous structure as well. The limited number of studies published on wind loads on elevated vertical panels shows that more research for validation and expansion of existing results is necessary. Design codes prove themselves to be complete and useful guidebooks. However, discrepancies that appear regarding a number of the provisions of vertical panels shows that they could go through further refinement. © 2012 Elsevier Ltd. en
heal.journalName Journal of Wind Engineering and Industrial Aerodynamics en
dc.identifier.volume 107-108 en
dc.identifier.doi 10.1016/j.jweia.2012.02.014 en
dc.identifier.spage 1 en
dc.identifier.epage 16 en