HEAL DSpace

Simultaneous quantification of 17α-OH progesterone, 11-deoxycortisol, Δ4-androstenedione, cortisol and cortisone in newborn blood spots using liquid chromatography-tandem mass spectrometry

Αποθετήριο DSpace/Manakin

Εμφάνιση απλής εγγραφής

dc.contributor.author Magnisali, P en
dc.contributor.author Chalioti, M-B en
dc.contributor.author Livadara, T en
dc.contributor.author Mataragas, M en
dc.contributor.author Paliatsiou, S en
dc.contributor.author Malamitsi-Puchner, A en
dc.contributor.author Moutsatsou, P en
dc.date.accessioned 2014-06-06T06:51:32Z
dc.date.available 2014-06-06T06:51:32Z
dc.date.issued 2011 en
dc.identifier.issn 15700232 en
dc.identifier.uri http://dx.doi.org/10.1016/j.jchromb.2011.03.048 en
dc.identifier.uri http://62.217.125.90/xmlui/handle/123456789/5564
dc.subject Δ4-Androstenedione en
dc.subject 11-Deoxycortisol en
dc.subject 17α-OH progesterone en
dc.subject Blood spots en
dc.subject Cortisol en
dc.subject Cortisone en
dc.subject Tandem mass spectrometry en
dc.subject.other 11-deoxycortisol en
dc.subject.other Aqueous solutions en
dc.subject.other Congenital adrenal hyperplasias en
dc.subject.other Cortisol en
dc.subject.other Cortisone en
dc.subject.other Detection limits en
dc.subject.other Diethyl ethers en
dc.subject.other Dried blood spots en
dc.subject.other Elevated level en
dc.subject.other Internal standards en
dc.subject.other LC-MS/MS en
dc.subject.other Limit of quantifications en
dc.subject.other Liquid chromatography-tandem mass spectrometry en
dc.subject.other Newborn screening en
dc.subject.other Routine analysis en
dc.subject.other Sample manipulation en
dc.subject.other Sample processing en
dc.subject.other Serum samples en
dc.subject.other Steroid profiling en
dc.subject.other Tandem mass spectrometry en
dc.subject.other Whole blood en
dc.subject.other Deuterium en
dc.subject.other Lipids en
dc.subject.other Liquid chromatography en
dc.subject.other Mass spectrometry en
dc.subject.other Solutions en
dc.subject.other Solvent extraction en
dc.subject.other Blood en
dc.subject.other androstenedione en
dc.subject.other cortisone en
dc.subject.other cortodoxone en
dc.subject.other deuterium en
dc.subject.other ether en
dc.subject.other hydrocortisone en
dc.subject.other hydroxyprogesterone en
dc.subject.other accuracy en
dc.subject.other aqueous solution en
dc.subject.other article en
dc.subject.other blood en
dc.subject.other controlled study en
dc.subject.other elution en
dc.subject.other evaporation en
dc.subject.other extraction en
dc.subject.other female en
dc.subject.other human en
dc.subject.other limit of quantitation en
dc.subject.other liquid chromatography en
dc.subject.other male en
dc.subject.other newborn en
dc.subject.other normal human en
dc.subject.other priority journal en
dc.subject.other purification en
dc.subject.other reference value en
dc.subject.other standard en
dc.subject.other tandem mass spectrometry en
dc.subject.other validation process en
dc.subject.other 17-alpha-Hydroxyprogesterone en
dc.subject.other Androstenedione en
dc.subject.other Blood Specimen Collection en
dc.subject.other Chromatography, Liquid en
dc.subject.other Cortisone en
dc.subject.other Cortodoxone en
dc.subject.other Female en
dc.subject.other Humans en
dc.subject.other Hydrocortisone en
dc.subject.other Infant, Newborn en
dc.subject.other Linear Models en
dc.subject.other Male en
dc.subject.other Reproducibility of Results en
dc.subject.other Sensitivity and Specificity en
dc.subject.other Tandem Mass Spectrometry en
dc.title Simultaneous quantification of 17α-OH progesterone, 11-deoxycortisol, Δ4-androstenedione, cortisol and cortisone in newborn blood spots using liquid chromatography-tandem mass spectrometry en
heal.type journalArticle en
heal.identifier.primary 10.1016/j.jchromb.2011.03.048 en
heal.publicationDate 2011 en
heal.abstract Adrenal steroid profiling, including 17α-OH progesterone (17OHP), 11-deoxycortisol (S), Δ4-androstenedione (Δ4-A) and cortisol (F) in blood spots by tandem mass spectrometry, is used for newborn screening to detect congenital adrenal hyperplasia (CAH). Pre-analytical sample processing is critical for assay specificity and accuracy; however, it is laborious and time-consuming. This study describes the development and validation of a new Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS) method for the simultaneous quantification of five steroids: 17OHP, S, Δ4-A, F and cortisone (E) in blood spots from newborns. Whole blood was eluted from a 5.00. mm dried blood spot by an aqueous solution containing the deuterium-labeled internal standards d8-17OHP and d4-cortisol. The steroids extracted from blood spot into aqueous solution were subsequently purified via Extelut mini NT1 column using diethylether. The extracts were evaporated and quantified using LC-MS/MS. The detection limit was 0.25. ng/mL for 17OHP and S, 0.4. ng/mL for Δ4-A and 0.5. ng/mL for F and E. The limit of quantification was 0.5. ng/mL for 17OHP, S and Δ4-A and 1. ng/mL for F and E. Precision for 17OHP, S, Δ4-A at concentrations of 0.5, 2, and 8. ng/mL (n= 5) in fortified steroid free serum samples was 1.3-3.5% (intra-assay CV) and 7-14.8% (inter-assay CV). Precision for F and E at concentrations of 5 and 20. ng/mL was 1.5-4.8% (intra-assay, CV%) and 6-15% (inter-assay, CV%). Accuracy was calculated at concentrations of 0.5, 2, and 8. ng/mL for 17OHP, S and Δ4-A and ranged from -0.3 to 0.2%, while for F and E it ranged from -3.2 to 0.2%. Relative recoveries at concentration 2. ng/mL and 8. ng/mL for 17OHP, S, Δ4-A and at 5. ng/mL and 20. ng/mL for F and E ranged from 55% to 80%. Reference intervals were estimated for all steroids in newborns (on day 3). The steroid profile assay herein described is sensitive, specific and accurate and involves a simple pre-analytical sample manipulation; it is therefore suitable for routine analysis and provides data for samples within normal range as well as those with elevated levels. For the first time to our knowledge, cortisone levels are reported in dried blood spots from newborns. © 2011 Elsevier B.V. en
heal.journalName Journal of Chromatography B: Analytical Technologies in the Biomedical and Life Sciences en
dc.identifier.issue 19 en
dc.identifier.volume 879 en
dc.identifier.doi 10.1016/j.jchromb.2011.03.048 en
dc.identifier.spage 1565 en
dc.identifier.epage 1572 en


Αρχεία σε αυτό το τεκμήριο

Αρχεία Μέγεθος Μορφότυπο Προβολή

Δεν υπάρχουν αρχεία που σχετίζονται με αυτό το τεκμήριο.

Αυτό το τεκμήριο εμφανίζεται στην ακόλουθη συλλογή(ές)

Εμφάνιση απλής εγγραφής

Αναζήτηση DSpace


Σύνθετη Αναζήτηση

Αναζήτηση

Ο Λογαριασμός μου

Στατιστικές