Investigation on the SEL Sensitive Depth of an SRAM Using Linear and Two-Photon Absorption Laser Testing

Αποθετήριο DSpace/Manakin

Εμφάνιση απλής εγγραφής

dc.contributor.author Faraud, E en
dc.contributor.author Pouget, V en
dc.contributor.author Shao, K en
dc.contributor.author Larue, C en
dc.contributor.author Darracq, F en
dc.contributor.author Lewis, D en
dc.contributor.author Samaras, A en
dc.contributor.author Bezerra, F en
dc.contributor.author Lorfevre, E en
dc.contributor.author Ecoffet, R en
dc.date.accessioned 2014-06-06T06:51:09Z
dc.date.available 2014-06-06T06:51:09Z
dc.date.issued 2011 en
dc.identifier.uri http://dx.doi.org/10.1109/TNS.2011.2172222 en
dc.identifier.uri http://62.217.125.90/xmlui/handle/123456789/5347
dc.subject Heavy Ions en
dc.subject Optical Imaging en
dc.subject Two Photon Absorption en
dc.title Investigation on the SEL Sensitive Depth of an SRAM Using Linear and Two-Photon Absorption Laser Testing en
heal.type journalArticle en
heal.identifier.primary 10.1109/TNS.2011.2172222 en
heal.publicationDate 2011 en
heal.abstract Linear and two-photon laser testing is used to investigate the single-event latchup sensitive depth of SRAM CY7C1069 embedded in CARMEN satellite experiment. Results are discussed and compared with heavy ion and flight data. en
heal.journalName IEEE Transactions on Nuclear Science en
dc.identifier.doi 10.1109/TNS.2011.2172222 en


Αρχεία σε αυτό το τεκμήριο

Αρχεία Μέγεθος Μορφότυπο Προβολή

Δεν υπάρχουν αρχεία που σχετίζονται με αυτό το τεκμήριο.

Αυτό το τεκμήριο εμφανίζεται στην ακόλουθη συλλογή(ές)

Εμφάνιση απλής εγγραφής

Αναζήτηση DSpace


Σύνθετη Αναζήτηση

Αναζήτηση

Ο Λογαριασμός μου

Στατιστικές