HEAL DSpace

WET Sensor Performance in Organic and Inorganic Media with Heterogeneous Moisture Distribution

Αποθετήριο DSpace/Manakin

Εμφάνιση απλής εγγραφής

dc.contributor.author Kargas, G en
dc.contributor.author Kerkides, P en
dc.contributor.author Seyfried, M en
dc.contributor.author Sgoumbopoulou, A en
dc.date.accessioned 2014-06-06T06:51:07Z
dc.date.available 2014-06-06T06:51:07Z
dc.date.issued 2011 en
dc.identifier.issn 0361-5995 en
dc.identifier.uri http://62.217.125.90/xmlui/handle/123456789/5334
dc.subject.classification Soil Science en
dc.subject.other TIME-DOMAIN REFLECTOMETRY en
dc.subject.other SOIL-WATER CONTENT en
dc.subject.other DIFFERENT DIELECTRIC METHODS en
dc.subject.other SALINE GYPSIFEROUS SOIL en
dc.subject.other ELECTROMAGNETIC DETERMINATION en
dc.subject.other ELECTRICAL-CONDUCTIVITY en
dc.subject.other CALIBRATION en
dc.subject.other TDR en
dc.subject.other TEMPERATURE en
dc.subject.other PROBE en
dc.title WET Sensor Performance in Organic and Inorganic Media with Heterogeneous Moisture Distribution en
heal.type journalArticle en
heal.language English en
heal.publicationDate 2011 en
heal.abstract Interest in electronic monitoring of soil water has grown as increased demand for water creates a greater need for effective water management. Relatively inexpensive commercial soil water sensors that use measured soil dielectric properties to calculate soil water content have been developed to address this need but have received little independent testing of critical calibration procedures and parameters. The WET sensor (Delta-T Devices, Cambridge, UK) is one such sensor. The two primary objectives in this study were to: (i) determine appropriate calibration parameters for a variety of inorganic soils and organic media; and (ii) determine how WET sensor readings are affected in media with strongly contrasting water contents. We found that the two-point calibrations suggested by the manufacturer yielded parameters that were not significantly different (alpha = 0.05) from those suggested by the manufacturer and yielded values consistent with well-established oven-dry values. For the organic media, we found that accurate, media-specific calibration could be obtained for all media tested and that the general form of the calibration equation used for soils applies to organic media. Experiments in a variety of layered media showed that, in contrast to time domain reflectometry results, the WET-measured dielectric value is the arithmetic average of the two contrasting layers. In soils, the linear correlation between measured and arithmetic average dielectric constants was very high (R-2 > 0.99) for all four soils tested. This indicates that the upward infiltration calibration technique is generally inappropriate for the WET sensor. en
heal.publisher SOIL SCI SOC AMER en
heal.journalName SOIL SCIENCE SOCIETY OF AMERICA JOURNAL en
dc.identifier.issue 4 en
dc.identifier.volume 75 en
dc.identifier.isi ISI:000293076400005 en
dc.identifier.spage 1244 en
dc.identifier.epage 1252 en


Αρχεία σε αυτό το τεκμήριο

Αρχεία Μέγεθος Μορφότυπο Προβολή

Δεν υπάρχουν αρχεία που σχετίζονται με αυτό το τεκμήριο.

Αυτό το τεκμήριο εμφανίζεται στην ακόλουθη συλλογή(ές)

Εμφάνιση απλής εγγραφής

Αναζήτηση DSpace


Σύνθετη Αναζήτηση

Αναζήτηση

Ο Λογαριασμός μου

Στατιστικές