dc.contributor.author |
Trabelsi, S |
en |
dc.contributor.author |
Lewis, MA |
en |
dc.contributor.author |
Nelson, SO |
en |
dc.date.accessioned |
2014-06-06T06:49:01Z |
|
dc.date.available |
2014-06-06T06:49:01Z |
|
dc.date.issued |
2009 |
en |
dc.identifier.uri |
http://62.217.125.90/xmlui/handle/123456789/4385 |
|
dc.relation.uri |
http://www.scopus.com/inward/record.url?eid=2-s2.0-77649103948&partnerID=40&md5=0315246557c8b22aabd9ce9084903bb0 |
en |
dc.subject |
Density-independent function |
en |
dc.subject |
Dielectric properties |
en |
dc.subject |
Microwave measurements |
en |
dc.subject |
Moisture content |
en |
dc.subject |
Peanut kernels |
en |
dc.subject |
Peanut pods |
en |
dc.subject |
Temperature |
en |
dc.subject.other |
A-density |
en |
dc.subject.other |
Calibration equations |
en |
dc.subject.other |
Density-independent function |
en |
dc.subject.other |
Dimensional representation |
en |
dc.subject.other |
Focused beams |
en |
dc.subject.other |
Free space |
en |
dc.subject.other |
Lens antenna |
en |
dc.subject.other |
Moisture content |
en |
dc.subject.other |
Moisture contents |
en |
dc.subject.other |
Nondestructive determination |
en |
dc.subject.other |
Standard error of calibrations |
en |
dc.subject.other |
Temperature correction |
en |
dc.subject.other |
Vector network analyzers |
en |
dc.subject.other |
Calibration |
en |
dc.subject.other |
Dielectric properties |
en |
dc.subject.other |
Electric network analysis |
en |
dc.subject.other |
Electric network analyzers |
en |
dc.subject.other |
Horn antennas |
en |
dc.subject.other |
Lens antennas |
en |
dc.subject.other |
Microwave measurement |
en |
dc.subject.other |
Microwaves |
en |
dc.subject.other |
Moisture |
en |
dc.subject.other |
Vector spaces |
en |
dc.subject.other |
Moisture determination |
en |
dc.title |
Rapid and nondestructive determination of moisture content in peanut kernels from microwave measurement of dielectric properties of pods |
en |
heal.type |
conferenceItem |
en |
heal.publicationDate |
2009 |
en |
heal.abstract |
A method for moisture determination in peanut kernels from measurement of the dielectric properties of peanut pods at microwave frequencies is presented. The dielectric properties of peanut kernels and pods were measured in free space with a vector network analyzer and a pair of focused beam horn-lens antennas. A density-independent algorithm was used to determine moisture content in peanut kernels and pods. Moisture calibration equations with temperature correction were determined from a three-dimensional representation, and an explicit relationship between peanut pod moisture content and kernel moisture content was identified. Results presented at 6 GHz and temperatures ranging from 0.5°C to 58°C show that kernel moisture content can be predicted with a standard error of calibration of 0.79% and that of pods with a standard error of calibration of 0.95%. |
en |
heal.journalName |
American Society of Agricultural and Biological Engineers Annual International Meeting 2009 |
en |
dc.identifier.volume |
9 |
en |
dc.identifier.spage |
5682 |
en |
dc.identifier.epage |
5689 |
en |