dc.contributor.author |
Trabelsi, S |
en |
dc.contributor.author |
Nelson, SO |
en |
dc.contributor.author |
Lewis, MA |
en |
dc.date.accessioned |
2014-06-06T06:48:13Z |
|
dc.date.available |
2014-06-06T06:48:13Z |
|
dc.date.issued |
2008 |
en |
dc.identifier.uri |
http://62.217.125.90/xmlui/handle/123456789/4021 |
|
dc.relation.uri |
http://www.scopus.com/inward/record.url?eid=2-s2.0-63049094253&partnerID=40&md5=c0259424420d7d7cd7521c77482567b7 |
en |
dc.subject |
Bulk density |
en |
dc.subject |
Dielectric properties |
en |
dc.subject |
Free space |
en |
dc.subject |
Microwave frequencies |
en |
dc.subject |
Moisture content |
en |
dc.subject |
Pine pellets |
en |
dc.subject.other |
A densities |
en |
dc.subject.other |
Bulk density |
en |
dc.subject.other |
Calibration functions |
en |
dc.subject.other |
Free space |
en |
dc.subject.other |
Microwave dielectrics |
en |
dc.subject.other |
Moisture content |
en |
dc.subject.other |
Non-destructive |
en |
dc.subject.other |
Pine pellets |
en |
dc.subject.other |
Standard error of calibrations |
en |
dc.subject.other |
Calibration |
en |
dc.subject.other |
Ceramic capacitors |
en |
dc.subject.other |
Dielectric properties |
en |
dc.subject.other |
Dielectric spectroscopy |
en |
dc.subject.other |
Microwave frequencies |
en |
dc.subject.other |
Moisture |
en |
dc.subject.other |
Pelletizing |
en |
dc.subject.other |
Softwoods |
en |
dc.subject.other |
Moisture determination |
en |
dc.title |
Use of dielectric spectroscopy for pelleted biofuels characterization |
en |
heal.type |
conferenceItem |
en |
heal.publicationDate |
2008 |
en |
heal.abstract |
A microwave dielectric method for nondestructive instantaneous determination of bulk density and moisture content of pine pellets is presented. The method is based on measurement of dielectric properties, eε' and ε″, at microwave frequencies. Bulk density was determined from a complex-plane representation of the dielectric properties and does not require moisture content and temperature to be known. Moisture content was determined from measured eεand eε' independent of bulk density with a density-independent calibration function. The standard error of calibration for bulk density was about 0.02 g/cm3 and that of moisture content was about 0.4%. |
en |
heal.journalName |
American Society of Agricultural and Biological Engineers Annual International Meeting 2008 |
en |
dc.identifier.volume |
8 |
en |
dc.identifier.spage |
4660 |
en |
dc.identifier.epage |
4667 |
en |