HEAL DSpace

Use of dielectric spectroscopy for pelleted biofuels characterization

Αποθετήριο DSpace/Manakin

Εμφάνιση απλής εγγραφής

dc.contributor.author Trabelsi, S en
dc.contributor.author Nelson, SO en
dc.contributor.author Lewis, MA en
dc.date.accessioned 2014-06-06T06:48:13Z
dc.date.available 2014-06-06T06:48:13Z
dc.date.issued 2008 en
dc.identifier.uri http://62.217.125.90/xmlui/handle/123456789/4021
dc.relation.uri http://www.scopus.com/inward/record.url?eid=2-s2.0-63049094253&partnerID=40&md5=c0259424420d7d7cd7521c77482567b7 en
dc.subject Bulk density en
dc.subject Dielectric properties en
dc.subject Free space en
dc.subject Microwave frequencies en
dc.subject Moisture content en
dc.subject Pine pellets en
dc.subject.other A densities en
dc.subject.other Bulk density en
dc.subject.other Calibration functions en
dc.subject.other Free space en
dc.subject.other Microwave dielectrics en
dc.subject.other Moisture content en
dc.subject.other Non-destructive en
dc.subject.other Pine pellets en
dc.subject.other Standard error of calibrations en
dc.subject.other Calibration en
dc.subject.other Ceramic capacitors en
dc.subject.other Dielectric properties en
dc.subject.other Dielectric spectroscopy en
dc.subject.other Microwave frequencies en
dc.subject.other Moisture en
dc.subject.other Pelletizing en
dc.subject.other Softwoods en
dc.subject.other Moisture determination en
dc.title Use of dielectric spectroscopy for pelleted biofuels characterization en
heal.type conferenceItem en
heal.publicationDate 2008 en
heal.abstract A microwave dielectric method for nondestructive instantaneous determination of bulk density and moisture content of pine pellets is presented. The method is based on measurement of dielectric properties, eε' and ε″, at microwave frequencies. Bulk density was determined from a complex-plane representation of the dielectric properties and does not require moisture content and temperature to be known. Moisture content was determined from measured eεand eε' independent of bulk density with a density-independent calibration function. The standard error of calibration for bulk density was about 0.02 g/cm3 and that of moisture content was about 0.4%. en
heal.journalName American Society of Agricultural and Biological Engineers Annual International Meeting 2008 en
dc.identifier.volume 8 en
dc.identifier.spage 4660 en
dc.identifier.epage 4667 en


Αρχεία σε αυτό το τεκμήριο

Αρχεία Μέγεθος Μορφότυπο Προβολή

Δεν υπάρχουν αρχεία που σχετίζονται με αυτό το τεκμήριο.

Αυτό το τεκμήριο εμφανίζεται στην ακόλουθη συλλογή(ές)

Εμφάνιση απλής εγγραφής

Αναζήτηση DSpace


Σύνθετη Αναζήτηση

Αναζήτηση

Ο Λογαριασμός μου

Στατιστικές