Comparison of external and internal standard methods in pesticide residue determinations

Αποθετήριο DSpace/Manakin

Εμφάνιση απλής εγγραφής

dc.contributor.author Anagnostopoulos, C en
dc.contributor.author Miliadis, GE en
dc.contributor.author Aplada-Sarlis, P en
dc.contributor.author Ziogas, BN en
dc.date.accessioned 2014-06-06T06:47:02Z
dc.date.available 2014-06-06T06:47:02Z
dc.date.issued 2006 en
dc.identifier.issn 03067319 en
dc.identifier.uri http://dx.doi.org/10.1080/03067310500249799 en
dc.identifier.uri http://62.217.125.90/xmlui/handle/123456789/3351
dc.subject External standard en
dc.subject Internal standard en
dc.subject Pesticide residues en
dc.subject.other Correlation methods en
dc.subject.other Detectors en
dc.subject.other Gas chromatography en
dc.subject.other Nitrogen en
dc.subject.other Phosphorus en
dc.subject.other Solvent extraction en
dc.subject.other Statistical methods en
dc.subject.other Correlation coefficients en
dc.subject.other External standard en
dc.subject.other Internal standard en
dc.subject.other Pesticide residues en
dc.subject.other Pesticides en
dc.title Comparison of external and internal standard methods in pesticide residue determinations en
heal.type conferenceItem en
heal.identifier.primary 10.1080/03067310500249799 en
heal.publicationDate 2006 en
heal.abstract A qualitative and quantitative gas-chromatographic pesticide-residue analysis method for 21 pesticides sensitive to the nitrogen-phosphorus detector was evaluated. The two methods of quantitative determination that were compared were the external standard (ES) method and the internal standard (IS) method. The methods were evaluated for the precision and linearity of the detector response. Precision was assessed by examining repeatability and reproducibility of the detector response. The RSD values found were lower than 20%. A better repeatability and reproducibility were observed with the IS method. The linearity of the detector was found to be satisfactory; by comparing the correlation coefficients found by the two methods, no significant difference was observed. The results were evaluated for the effect of the following factors: solvent of the final extract and time of determination. From a statistical comparison of the results of the IS and the ES methods, it was found that with the ES method, both factors were significant for the determination, and there was correlation between the two factors. With the IS method, only the solvent of the final extract had a significant effect on the results and no correlation was observed in most cases between the two factors. © 2005 Taylor & Francis. en
heal.journalName International Journal of Environmental Analytical Chemistry en
dc.identifier.issue 1-2 en
dc.identifier.volume 86 en
dc.identifier.doi 10.1080/03067310500249799 en
dc.identifier.spage 77 en
dc.identifier.epage 82 en


Αρχεία σε αυτό το τεκμήριο

Αρχεία Μέγεθος Μορφότυπο Προβολή

Δεν υπάρχουν αρχεία που σχετίζονται με αυτό το τεκμήριο.

Αυτό το τεκμήριο εμφανίζεται στην ακόλουθη συλλογή(ές)

Εμφάνιση απλής εγγραφής

Αναζήτηση DSpace


Σύνθετη Αναζήτηση

Αναζήτηση

Ο Λογαριασμός μου

Στατιστικές