HEAL DSpace

Vertical loads due to wheat on obstructions located on the floor of a model bin

Αποθετήριο DSpace/Manakin

Εμφάνιση απλής εγγραφής

dc.contributor.author Molenda, M en
dc.contributor.author Montross, MD en
dc.contributor.author Thompson, SA en
dc.contributor.author Horabik, J en
dc.date.accessioned 2014-06-06T06:46:51Z
dc.date.available 2014-06-06T06:46:51Z
dc.date.issued 2006 en
dc.identifier.issn 21510032 en
dc.identifier.uri http://62.217.125.90/xmlui/handle/123456789/3235
dc.relation.uri http://www.scopus.com/inward/record.url?eid=2-s2.0-33947159700&partnerID=40&md5=7dfb0f6325e299625faca58493bfa0f2 en
dc.subject Granular en
dc.subject Internal object en
dc.subject Janssen's equation en
dc.subject Obstructions en
dc.subject Silo en
dc.subject.other Galvanized steel walls en
dc.subject.other Janssen equations en
dc.subject.other Vertical loads en
dc.subject.other Bins en
dc.subject.other Corrugated containers en
dc.subject.other Filling en
dc.subject.other Galvanized metal en
dc.subject.other Grain (agricultural product) en
dc.subject.other bending en
dc.subject.other loading test en
dc.subject.other pressure gradient en
dc.subject.other silo en
dc.subject.other steel structure en
dc.subject.other wheat en
dc.subject.other Bins en
dc.subject.other Corrugated Boxes en
dc.subject.other Filling en
dc.subject.other Grain en
dc.subject.other Granules en
dc.subject.other Triticum aestivum en
dc.title Vertical loads due to wheat on obstructions located on the floor of a model bin en
heal.type journalArticle en
heal.publicationDate 2006 en
heal.abstract Tests were conducted in a model grain bin to evaluate the vertical loads acting on differently shaped obstructions embedded in wheat during filling, detention, and discharge. The bin had corrugated galvanized steel walls with a 1.83 m diameter and a flat bottom. All tests were conducted in a bin that was centrically loaded and unloaded. Three differently shaped obstructions (disc, cone, and cylinder) were tested; each had a circular base equivalent to 6% of the bin floor area. The obstructions were supported in the bin using a three-legged support structure. Each leg of the support structure rested on a load cell attached to the bin floor. Tests were conducted with the obstructions located in the bin at three different eccentricity ratios (ratio of the centerline of the obstruction to the bin radius, ER = 0, 0.5, and 0.67) and at two different grain heights (height of grain depth to bin diameter ratio, H/D = 0.4 and 0.75). The radial distribution of vertical pressures in the bin varied, with the highest pressure in the center of the bin and the lowest at the bin wall. The largest vertical load on the disc and cone obstructions was measured at the end of filling. The largest load on the cylindrical obstruction was observed immediately after the initiation of bin discharge. At the end of filling and detention, the vertical loads on the disc, cone, and cylinder were 4.8, 3.7, and 4.9 kN, respectively, for obstructions located at ER = 0 and H/D = 0.4. At a location closest to the bin wall (ER = 0.67), the vertical loading on the disc, cone, and cylinder were 4.4, 3.4, and 4.4 kN, respectively. The greatest difference in vertical loading between the location and type of obstruction was on the order of 50%. Bending moments were also observed to act on these obstructions. Bending moments at ER = 0.67 were much larger than those determined at ER = 0.5. For the disc and cone, moments at ER = 0.67 were three times as large as those determined for tests conducted at ER = 0.0. At the onset of discharge, the vertical loading on both the disc and cone decreased significantly, while the vertical loading on the cylinder increased significantly. Recommendations based on Eurocode I were used to predict the vertical loading on the disc and cylinder embedded in grain. This technique did an adequate job of predicting the maximum loading on both obstructions within the bin; however, it did not take into account the effect of unloading on the obstruction forces. © 2006 American Society of Agricultural and Biological Engineers. en
heal.journalName Transactions of the ASABE en
dc.identifier.issue 6 en
dc.identifier.volume 49 en
dc.identifier.spage 1855 en
dc.identifier.epage 1865 en