HEAL DSpace

Determination of Uronic Acids in Isolated Hemicelluloses from Kenaf Using Diffuse Reflectance Infrared Fourier Transform Spectroscopy (DRIFTS) and the Curve-Fitting Deconvolution Method

Αποθετήριο DSpace/Manakin

Εμφάνιση απλής εγγραφής

dc.contributor.author Batsoulis, AN en
dc.contributor.author Nacos, MK en
dc.contributor.author Pappas, CS en
dc.contributor.author Tarantilis, PA en
dc.contributor.author Mavromoustakos, T en
dc.contributor.author Polissiou, MG en
dc.date.accessioned 2014-06-06T06:45:57Z
dc.date.available 2014-06-06T06:45:57Z
dc.date.issued 2004 en
dc.identifier.issn 00037028 en
dc.identifier.uri http://dx.doi.org/10.1366/000370204322842931 en
dc.identifier.uri http://62.217.125.90/xmlui/handle/123456789/2727
dc.subject Deconvolution en
dc.subject Diffuse reflectance infrared Fourier transform spectroscopy en
dc.subject DRIFTS en
dc.subject Hemicelluloses en
dc.subject Kenaf en
dc.subject Uronic acids en
dc.subject.other Cellulose en
dc.subject.other Curve fitting en
dc.subject.other Fourier transform infrared spectroscopy en
dc.subject.other Functions en
dc.subject.other Light absorption en
dc.subject.other Lipids en
dc.subject.other Pigments en
dc.subject.other Proteins en
dc.subject.other Salts en
dc.subject.other Spectrophotometry en
dc.subject.other Sugars en
dc.subject.other Ultraviolet spectroscopy en
dc.subject.other Deconvolution en
dc.subject.other Diffuse reflectance infrared fourier transform spectroscopy (DRIFTS) en
dc.subject.other DRIFTS en
dc.subject.other Hemicelluloses en
dc.subject.other Kenaf en
dc.subject.other Uronic acids en
dc.subject.other Organic acids en
dc.title Determination of Uronic Acids in Isolated Hemicelluloses from Kenaf Using Diffuse Reflectance Infrared Fourier Transform Spectroscopy (DRIFTS) and the Curve-Fitting Deconvolution Method en
heal.type journalArticle en
heal.identifier.primary 10.1366/000370204322842931 en
heal.publicationDate 2004 en
heal.abstract Hemicellulose samples were isolated from kenaf (Hibiscus cannabinus L.). Hemicellulosic fractions usually contain a variable percentage of uronic acids. The uronic acid content (expressed in polygalacturonic acid) of the isolated hemicelluloses was determined by diffuse reflectance infrared Fourier transform spectroscopy (DRIFTS) and the curve-fitting deconvolution method. A linear relationship between uronic acids content and the sum of the peak areas at 1745, 1715, and 1600 cm-1 was established with a high correlation coefficient (0.98). The deconvolution analysis using the curve-fitting method allowed the elimination of spectral interferences from other cell wall components. The above method was compared with an established spectrophotometric method and was found equivalent for accuracy and repeatability (t-test, F-test). This method is applicable in analysis of natural or synthetic mixtures and/or crude substances. The proposed method is simple, rapid, and nondestructive for the samples. en
heal.journalName Applied Spectroscopy en
dc.identifier.issue 2 en
dc.identifier.volume 58 en
dc.identifier.doi 10.1366/000370204322842931 en
dc.identifier.spage 199 en
dc.identifier.epage 202 en


Αρχεία σε αυτό το τεκμήριο

Αρχεία Μέγεθος Μορφότυπο Προβολή

Δεν υπάρχουν αρχεία που σχετίζονται με αυτό το τεκμήριο.

Αυτό το τεκμήριο εμφανίζεται στην ακόλουθη συλλογή(ές)

Εμφάνιση απλής εγγραφής

Αναζήτηση DSpace


Σύνθετη Αναζήτηση

Αναζήτηση

Ο Λογαριασμός μου

Στατιστικές