HEAL DSpace

Determination of the degree of esterification of pectinates with decyl and benzyl ester groups by diffuse reflectance infrared Fourier transform spectroscopy (DRIFTS) and curve-fitting deconvolution method

Αποθετήριο DSpace/Manakin

Εμφάνιση απλής εγγραφής

dc.contributor.author Pappas, CS en
dc.contributor.author Malovikova, A en
dc.contributor.author Hromadkova, Z en
dc.contributor.author Tarantilis, PA en
dc.contributor.author Ebringerova, A en
dc.contributor.author Polissiou, MG en
dc.date.accessioned 2014-06-06T06:45:57Z
dc.date.available 2014-06-06T06:45:57Z
dc.date.issued 2004 en
dc.identifier.issn 01448617 en
dc.identifier.uri http://dx.doi.org/10.1016/j.carbpol.2004.03.014 en
dc.identifier.uri http://62.217.125.90/xmlui/handle/123456789/2726
dc.subject Deconvolution en
dc.subject Degree of esterification en
dc.subject Diffuse reflectance infrared Fourier transform spectroscopy en
dc.subject Esters en
dc.subject Pectin en
dc.subject.other Curve fitting en
dc.subject.other Derivatives en
dc.subject.other Diffusion en
dc.subject.other Electromagnetic wave reflection en
dc.subject.other Esterification en
dc.subject.other Esters en
dc.subject.other Fourier transform infrared spectroscopy en
dc.subject.other Deconvolution en
dc.subject.other Degree of esterification en
dc.subject.other Pectin en
dc.subject.other Synthetic mixtures en
dc.subject.other Carbohydrates en
dc.title Determination of the degree of esterification of pectinates with decyl and benzyl ester groups by diffuse reflectance infrared Fourier transform spectroscopy (DRIFTS) and curve-fitting deconvolution method en
heal.type journalArticle en
heal.identifier.primary 10.1016/j.carbpol.2004.03.014 en
heal.publicationDate 2004 en
heal.abstract Pectinates with benzyl and decyl ester groups were prepared by alkylation of the tetrabutylammonium salt of pectic acid with benzyl and decyl bromides, respectively. The degree of esterification (DE) of the pectin derivatives was determined by diffuse reflectance infrared Fourier transform spectroscopy and the curve-fitting deconvolution method. A linear relationship between DE and the ratio of the peak area at 1745 cm-1 to the sum of the peak areas at 1745 and 1608 cm-1 was established with a high correlation coefficient 0.98. The deconvolution analysis using the curve-fitting method allowed the elimination of spectral interferences from pectin components and their degradation products. The limits of the method are given by DE 6 and 93%. The method was compared with chemical analysis and found to be equivalent in view of accuracy and repeatability (t-test, F-test). The method is applicable in analysis of natural or synthetic mixtures and/or crude pectin substances. © 2004 Elsevier Ltd. All rights reserved. en
heal.journalName Carbohydrate Polymers en
dc.identifier.issue 4 en
dc.identifier.volume 56 en
dc.identifier.doi 10.1016/j.carbpol.2004.03.014 en
dc.identifier.spage 465 en
dc.identifier.epage 469 en


Αρχεία σε αυτό το τεκμήριο

Αρχεία Μέγεθος Μορφότυπο Προβολή

Δεν υπάρχουν αρχεία που σχετίζονται με αυτό το τεκμήριο.

Αυτό το τεκμήριο εμφανίζεται στην ακόλουθη συλλογή(ές)

Εμφάνιση απλής εγγραφής

Αναζήτηση DSpace


Σύνθετη Αναζήτηση

Αναζήτηση

Ο Λογαριασμός μου

Στατιστικές