dc.contributor.author | Baynham, TC | en |
dc.contributor.author | Knisley, SB | en |
dc.date.accessioned | 2014-06-06T06:44:27Z | |
dc.date.available | 2014-06-06T06:44:27Z | |
dc.date.issued | 2001 | en |
dc.identifier.issn | 10453873 | en |
dc.identifier.uri | http://62.217.125.90/xmlui/handle/123456789/1883 | |
dc.relation.uri | http://www.scopus.com/inward/record.url?eid=2-s2.0-0034745611&partnerID=40&md5=038050120592e5eea7b5b0671da33750 | en |
dc.subject | Arrhythmias | en |
dc.subject | Line stimulation | en |
dc.subject | Transmembrane voltage | en |
dc.subject | Virtual electrodes | en |
dc.subject.other | action potential | en |
dc.subject.other | animal experiment | en |
dc.subject.other | animal tissue | en |
dc.subject.other | article | en |
dc.subject.other | electrostimulation | en |
dc.subject.other | fluorescence | en |
dc.subject.other | heart arrhythmia | en |
dc.subject.other | nonhuman | en |
dc.subject.other | polarization | en |
dc.subject.other | priority journal | en |
dc.subject.other | rabbit | en |
dc.subject.other | statistical analysis | en |
dc.subject.other | stimulus response | en |
dc.subject.other | animal | en |
dc.subject.other | computer simulation | en |
dc.subject.other | electrode | en |
dc.subject.other | heart | en |
dc.subject.other | pathophysiology | en |
dc.subject.other | physiology | en |
dc.subject.other | spectrofluorometry | en |
dc.subject.other | heart pacing | en |
dc.subject.other | methodology | en |
dc.subject.other | pericardium | en |
dc.subject.other | time | en |
dc.subject.other | Action Potentials | en |
dc.subject.other | Animals | en |
dc.subject.other | Arrhythmia | en |
dc.subject.other | Computer Simulation | en |
dc.subject.other | Data Interpretation, Statistical | en |
dc.subject.other | Electrodes | en |
dc.subject.other | Heart | en |
dc.subject.other | Rabbits | en |
dc.subject.other | Spectrometry, Fluorescence | en |
dc.subject.other | Cardiac Pacing, Artificial | en |
dc.subject.other | Electric Stimulation | en |
dc.subject.other | Electrodes, Implanted | en |
dc.subject.other | Pericardium | en |
dc.subject.other | Time Factors | en |
dc.title | Roles of line stimulation-induced virtual electrodes and action potential prolongation in arrhythmic propagation | en |
heal.type | journalArticle | en |
heal.publicationDate | 2001 | en |
heal.abstract | Arrhythmias During Line Stimulation. Introduction: Line stimulation across fibers generates a virtual electrode (VE) pattern that consists of adjacent +Vm and -Vm regions. In this study, we evaluated Vm at the break of line stimulation pulses to determine where arrhythmias arise and their propagation direction relative to +Vm and -Vm regions. Methods and Results: We optically mapped the anterior left ventricular epicardium of isolated rabbit hearts (n = 9). Monophasic line stimuli were applied across fibers at various coupling intervals. In 18 of 24 break arrhythmias, i.e., arrhythmias in which propagation occurred after the break but ≤30 msec postshock, excitation propagated from the border between +Vm and -Vm regions toward the -Vm region (P < 0.05) for either shock polarity, even though locations of positive and negative Vm changed with shock polarity. In 13 of 18 make arrhythmias, i.e., arrhythmias in which propagation occurred before the break, the excitation propagated from the center of the +Vm region toward the -Vm regions (P < 0.05). For late arrhythmias, i.e., arrhythmias in which propagation was found >30 msec postshock, propagation was reversed, i.e., toward the +Vm region (P < 0.01), which was where the positive VE produced action potential prolongation. Conclusion: The propagation of break, make, and late arrhythmias is spatially related to VEs. The different direction of propagation of late arrhythmias relative to the VEs is explained by the delayed recovery of Vm due to VE-induced action potential prolongation. | en |
heal.journalName | Journal of Cardiovascular Electrophysiology | en |
dc.identifier.issue | 2 | en |
dc.identifier.volume | 12 | en |
dc.identifier.spage | 256 | en |
dc.identifier.epage | 263 | en |
Αρχεία | Μέγεθος | Μορφότυπο | Προβολή |
---|---|---|---|
Δεν υπάρχουν αρχεία που σχετίζονται με αυτό το τεκμήριο. |