HEAL DSpace

FT-Raman spectroscopy - analytical tool for routine analysis of diazinon pesticide formulations

Αποθετήριο DSpace/Manakin

Εμφάνιση απλής εγγραφής

dc.contributor.author Skoulika, SG en
dc.contributor.author Georgiou, CA en
dc.contributor.author Polissiou, MG en
dc.date.accessioned 2014-06-06T06:44:23Z
dc.date.available 2014-06-06T06:44:23Z
dc.date.issued 2000 en
dc.identifier.issn 0039-9140 en
dc.identifier.uri http://62.217.125.90/xmlui/handle/123456789/1849
dc.subject diazinon en
dc.subject FT-Raman en
dc.subject pesticide formulations en
dc.subject determination en
dc.subject.classification Chemistry, Analytical en
dc.subject.other FOURIER-TRANSFORM RAMAN en
dc.subject.other QUANTITATIVE-ANALYSIS en
dc.subject.other QUALITATIVE-ANALYSIS en
dc.title FT-Raman spectroscopy - analytical tool for routine analysis of diazinon pesticide formulations en
heal.type journalArticle en
heal.language English en
heal.publicationDate 2000 en
heal.abstract FT-Raman spectroscopy based on band intensity and band area measurements, was used for the quantitative determination of diazinon in pesticide formulations. Bands at 554, 604, 631, 1562 and 2971 cm(-1) were used for calibration. Spectra were acquired by averaging 100 scans at a resolution of 4 cm(-1). Calibration curves were linear (correlation coefficients, 0.992-0.9992 and 0.99-0.999 for band intensity and band area measurements, respectively) in the range of 0.2-3.5 M for 554 and 2971 cm(-1), 0.3-3.5 M for 604 cm(-1), 0.6-3.5 M for 1562 cm(-1) and 1.0-3.5 M for 631 cm(-1) bands. Normalization of calibration curves against the 802 cm(-1) cyclohexane band improved their long term stability and minimized the effect of laser beam power fluctuations. No interference was found by commonly used surfactants and the proposed method was applied to the analysis of diazinon formulations. Results obtained compare well as indicated by the t-test, with those obtained by the HPLC reference method. Precision ranged between 0.2-7.8 and 0.1-7.2% RSD, (n = 4) for band intensity and band area measurements, respectively. The proposed method is rapid, simple and safe, as toxic samples are analyzed 'as received' without sample pre-treatment, permiting the routine analysis of pesticides formulations. (C) 2000 Elsevier Science B.V. All rights reserved. en
heal.publisher ELSEVIER SCIENCE BV en
heal.journalName TALANTA en
dc.identifier.issue 3 en
dc.identifier.volume 51 en
dc.identifier.isi ISI:000085712300021 en
dc.identifier.spage 599 en
dc.identifier.epage 604 en


Αρχεία σε αυτό το τεκμήριο

Αρχεία Μέγεθος Μορφότυπο Προβολή

Δεν υπάρχουν αρχεία που σχετίζονται με αυτό το τεκμήριο.

Αυτό το τεκμήριο εμφανίζεται στην ακόλουθη συλλογή(ές)

Εμφάνιση απλής εγγραφής

Αναζήτηση DSpace


Σύνθετη Αναζήτηση

Αναζήτηση

Ο Λογαριασμός μου

Στατιστικές