HEAL DSpace

Direct parallel flow injection multichannel spectrophotometric determination of olive oil peroxide value

Αποθετήριο DSpace/Manakin

Εμφάνιση απλής εγγραφής

dc.contributor.author Nouros, PG en
dc.contributor.author Georgiou, CA en
dc.contributor.author Polissiou, MG en
dc.date.accessioned 2014-06-06T06:44:02Z
dc.date.available 2014-06-06T06:44:02Z
dc.date.issued 1999 en
dc.identifier.issn 0003-2670 en
dc.identifier.uri http://62.217.125.90/xmlui/handle/123456789/1640
dc.subject olive oil en
dc.subject flow injection parallel analysis en
dc.subject flow reversal en
dc.subject peroxide value en
dc.subject multichannel analyser en
dc.subject incubation coils en
dc.subject.classification Chemistry, Analytical en
dc.subject.other HYDROPEROXIDES en
dc.subject.other FOODSTUFFS en
dc.title Direct parallel flow injection multichannel spectrophotometric determination of olive oil peroxide value en
heal.type journalArticle en
heal.language English en
heal.publicationDate 1999 en
heal.abstract An automated parallel flow injection (PA-FI) spectrophotometric method for the determination of peroxide value (PV, meg O-2 kg(-1) oil) in olive oil is described. A home-made PA-FI analyser incorporating 10 incubation coils and using flow reversals achieves a sampling rate of 83 samples h(-1) while each sample is incubated for 5 min. Detection is achieved by monitoring iodine liberated from NaI by lipid peroxides at 360 nm. The new PA-FI method allows olive oil analysis without pretreatment or dilution and minimizes solvent consumption (2.0 mi of acetic acid and 3.4 mi of n-propanol per analysis). Precision was found to be better than 2.0% relative standard deviation (n=10). The linear range was 2.5-80 PV, rendering the method useful for the analysis of edible olive oils. Results obtained by the proposed method compare well (0-5.6% relative difference, mean 1.0%) with those obtained by an official method that is time-consuming and uses large amounts of organic solvents. The PA-FI analyser developed allows automation of methods that require long incubation times without loss of sampling rate. Up to 60 samples h(-1) can be analysed when 10 min incubation time is required. The detector is inserted in the flow path before the incubation coils and incubated samples are aspirated back to the detector by flow reversal. This overcomes construction difficulties and allows the measurement of the sample blank value. (C) 1999 Elsevier Science B.V. All rights reserved. en
heal.publisher ELSEVIER SCIENCE BV en
heal.journalName ANALYTICA CHIMICA ACTA en
dc.identifier.issue 1-3 en
dc.identifier.volume 389 en
dc.identifier.isi ISI:000080527900027 en
dc.identifier.spage 239 en
dc.identifier.epage 245 en


Αρχεία σε αυτό το τεκμήριο

Αρχεία Μέγεθος Μορφότυπο Προβολή

Δεν υπάρχουν αρχεία που σχετίζονται με αυτό το τεκμήριο.

Αυτό το τεκμήριο εμφανίζεται στην ακόλουθη συλλογή(ές)

Εμφάνιση απλής εγγραφής

Αναζήτηση DSpace


Σύνθετη Αναζήτηση

Αναζήτηση

Ο Λογαριασμός μου

Στατιστικές