HEAL DSpace

Floor and wall pressures in a full-scale corrugated grain bin during unloading

Αποθετήριο DSpace/Manakin

Εμφάνιση απλής εγγραφής

dc.contributor.author Thompson, SA en
dc.contributor.author Galili, N en
dc.contributor.author Williams, RA en
dc.date.accessioned 2014-06-06T06:43:28Z
dc.date.available 2014-06-06T06:43:28Z
dc.date.issued 1998 en
dc.identifier.issn 00012351 en
dc.identifier.uri http://62.217.125.90/xmlui/handle/123456789/1297
dc.relation.uri http://www.scopus.com/inward/record.url?eid=2-s2.0-0032215545&partnerID=40&md5=47c2221d5fa4eea00b59cf55a75f67aa en
dc.subject Corrugated grain bins en
dc.subject Grain bins en
dc.subject Lateral pressures en
dc.subject Vertical pressures en
dc.subject.other Grain bins en
dc.subject.other Density (specific gravity) en
dc.subject.other Grain (agricultural product) en
dc.subject.other Pressure measurement en
dc.subject.other Unloading en
dc.subject.other Bins en
dc.title Floor and wall pressures in a full-scale corrugated grain bin during unloading en
heal.type journalArticle en
heal.publicationDate 1998 en
heal.abstract Vertical and lateral pressures were measured during unloading in a full-sized corrugated-walled grain bin using load cells placed at discrete locations on the floor and walls of the bin. The bin was a funnel flow bin in which no overpressures were observed. In observing the lateral wall pressures it appeared that some of the variation in the data can be attributed to the initial conditions in the bin in which some tests started with the bin empty and some tests started with the stagnant cone of grain in the bin. These differences were believed to be caused by differences in the in-bin bulk density and the spatial orientation of the grain during filling. This same phenomenon was not observed in the vertical floor pressures. During unloading the vertical floor pressures were observed to vary radially with the distance from the center of the bin with the pressures much smaller near the bin wall.Vertical and lateral pressures were measured during unloading in a full-sized corrugated-walled grain bin using load cells placed at discrete locations on the floor and walls of the bin. The bin was a funnel flow bin in which no overpressures were observed. In observing the lateral wall pressures it appeared that some of the variation in the data can be attributed to the initial conditions in the bin in which some tests started with the bin empty and some tests started with the stagnant cone of grain in the bin. These differences were believed to be caused by differences in the in-bin bulk density and the spatial orientation of the grain during filling. This same phenomenon was not observed in the vertical floor pressures. During unloading the vertical floor pressures were observed to vary radially with the distance from the center of the bin with the pressures much smaller near the bin wall. en
heal.journalName Transactions of the American Society of Agricultural Engineers en
dc.identifier.issue 6 en
dc.identifier.volume 41 en
dc.identifier.spage 1799 en
dc.identifier.epage 1805 en